Remineralisation systems:
- Pumping in the catchments,
- Degassing on stainless steel cascade,
- Degassed water and washing water tanks,
- Pumping for reinjection to filtration,
- Filtration on terrestrial limestone: 1 to 2 painted steel closed filters per plant, diameter 2.50 m,
- Washing: borewell type washing pump, air pressure booster,
- Terrestrial limestone storage silo (17 m3),
- Device to transfer the limestone into the filters by pumping,
- Bleach injection device for chlorination of treated water,
- Instrumentation (pH measurement, chlorine, turbidity, etc.)
- Electricity, automation system and supervision